OVERVIEW
Designed Specifically for Power Generation and Harsh Industrial Environments
- Guided Core design
- 1.05" (27mm) O.D. size body
- Stroke lengths from 3" to 16"
- Stainless steel housing sealed to IP68
Alliance Sensors Group's LA-27-A series LVDT linear position sensors are designed to handle extreme industrial environments. This robust linear sensor has a thick wall aluminum housing (also available in stainless steel), a core enclosed inside of the core extension rod assembly that cannot break loose, while offering a sturdy male thread for easy mechanical connection, and a pair of double contact shaft seals to keep fluids and solid contaminants out of its bore. The sensor’s electrical termination includes the choice of an axial connector or a cord grip with a cable.
An LA-27-A LVDT is ideal for roller gap positioning, head box feedback, process valve displacement, and actuator position feedback with the durability to withstand the harsh environments found in steam and hydro power plants; paper, steel, and aluminum mills; and industrial automation and fluid power systems. It can operate in such hostile factory environments as lubricant mist, cutting oil spray, and airborne grit or dust, and it survives typical industrial steam cleaning and wash downs.
Mated with ASG’s SC-200 industrial LVDT DIN-rail-mountable signal conditioner, the LA-27-A LVDT becomes an ideal solution for heavy duty industrial applications requiring position sensing. For operating an LA-27-A as a steam valve position sensor in a power plant, ASG’s model S2A signal conditioner, which is designed specifically for that application, is recommended.
Options:
TECHNICAL SPECIFICATIONS
Available FS Ranges: | 0 to 3, 6, 9, 12, 15, or 16 inches (0 to 75, 150, 225, 300, 375, or 400 mm) |
Excitation Frequency: | 3 kHz nominal |
Excitation Voltage: | 3 V ACrms nominal |
Full Scale Output: | 0.83 ±10% V ACrms output (nom.) from differentially connected (S1-S2) secondaries (ref: 3 Vrms excitation); sum of secondaries output is constant over range for ratiometric (S1-S2)/(S1+S2) operation |
Linearity Error: | ≤±0.5% of FSO |
Operating Temperature: | -40 to 125 °C (-40 to 250 °F) |
Temperature Coefficient: | ≤±0.025% FSO/degree C |
Humidity: | 95% RH non-condensing |
Shock: | 1000 g, 11 msec. |
Vibration: | 5-20 Hz, 0.5 inch p-p; 20-2000 Hz, 4.2 g p-p |